ASTM D Standard Practice for Heat Aging of Plastics Without Load 1 1 x00a0 This practice is intended to define the exposure conditions for evaluating. Standard Practice for Heat Aging of Plastics Without Load – ASTM D Status: Withdrawn ยท Replaced by: ASTM D Buy this standard. Price: . ASTM D(). Standard Practice for Heat Aging of Plastics Without Load. standard by ASTM International, 03/15/ This document has been.

Author: Bakinos Tygogrel
Country: Ethiopia
Language: English (Spanish)
Genre: Music
Published (Last): 27 August 2015
Pages: 243
PDF File Size: 3.66 Mb
ePub File Size: 20.69 Mb
ISBN: 458-8-14101-879-9
Downloads: 4142
Price: Free* [*Free Regsitration Required]
Uploader: Gasida

Ultimate properties such as strength or elongation are more sensitive to degradation than bulk properties such as modulus, in most cases. The property of interest is measured at room temperature.

ASTM D – Standard Practice for Heat Aging of Plastics Without Load

Normally, additional shrinkage should be expected with loss of volatiles or advance in polymerization. The effect of elevated temperature on any particular property is determined by selection of the appropriate test method and test specimens for that property. Only the procedure for heat exposure is specified.

Mechanical properties, such as flexural properties, are sensitive to heat degradation and may change at a more rapid rate. However, the data obtained from this practice, since it does not account for the influence of stress or environment that is involved in most real life applications, must be used cautiously by the designer, who must inevitably make material choices using additional data such as creep and creep rupture that asttm consistent with the requirements of the specific application.

Proceed to Checkout Continue Shopping. These transitions should be avoided both in the range of aging temperatures used, aetm well as in extrapolation of the lifeline.

  MANFRED ALBACH ELEKTROTECHNIK PDF

Certain asmt are susceptible to the influence of humidity. Please first log in with a verified email before subscribing to alerts.

We have no amendments or corrections for this standard. The severity of the exposures in both time and temperature determines the extent and type of change that takes place.

Specific properties and failure or lifetime criteria for these properties are typically chosen for the evaluation of thermal endurance. This standard and ISO address the same subject matter but differ in technical content. You aatm download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. Recommended procedures for determining the thermal aging characteristics of a material using a series of elevated temperatures for the purpose of estimating endurance time to a defined d33045 change at a lower temperature are also described; the applicability of the Arrhenius relation for making predictions to other d0345, is assumed in this case.

Therefore, for any application of the CUT or the TI temperature index to be valid, either the thermal aging program must duplicate the intended thermal exposure conditions of the end product, or the Arrhenius relation must apply.

The effect of elevated temperature on any particular property is determined by selection of the appropriate test method and test specimens for that property.

Standard Practice for Heat Aging of Plastics Without Load

Only the procedure for heat exposure is specified. Recommended procedures for determining the thermal aging characteristics of a material using a series of elevated temperatures for the purpose of estimating endurance time to a defined property change at a lower temperature are also described; the applicability of the Arrhenius relation for making predictions to other temperatures, is aetm in this case. Link to Active This wstm will always route to the current Active version of the standard.

  HERMETO CALENDARIO DO SOM PDF

Please first verify your email before subscribing to alerts.

You may delete a document from your Alert Profile at any time. Standards Subsctiption may be the perfect solution. This standard is not included in any packages.

Need more than one copy? It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. If the document is revised or amended, you will be notified by email. A plastic material is not d345 degraded by exposure to elevated temperatures.

As the voice of the U.

Caution should be exercised in using the Arrhenius relation and knowledge of physical changes in the material at elevated temperatures is important.

It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. This standard and ISO address the same subject matter but differ in technical content. Errors in exposure are cumulative with time.

Other types of plastics become soft and sticky, either due to sorption of volatilized plasticizer or due to breakdown of the polymer. The property of interest is measured at room temperature.

Add to Alert PDF. For instance, the arc resistance of thermosetting compounds improves up to the carbonization point of the material. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.